DWL@DWL10000538265

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.7.0.0 * 12.09.2025 4 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.7.0.0:

ID: TDYD-9355
The channel and configuration description has been adjusted, documentation updated.
The filters for the channel and configuration description have been adjusted.
The hardware documentation has been updated.
Channel description changed: Yes
Configurationdescription changed: Yes
Firmware changed: No
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290), 1\61870_3.fw(300)

Version 1.6.0.0:

ID: TDYD-7065
wac - File created for HW3
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290), 1\61870_3.fw(300)

Version 1.5.0.0:

ID: 779420
Support for new gyro sensor
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290), 1\61870_3.fw(300)

Version 1.4.0.0:

ID: 735050
SPI DMA proble fixed (SPI communication can get stuck)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 661970
New firmware
X2X+ problem solved (module failed sometimes at transition from SYNC to GO)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666225
Module documentation revised
Data sheet V 1.06
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(170), 1\61870_2.fw(270)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.6.0.0 * 04.09.2024 5 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.6.0.0:

ID: TDYD-7065
wac - File created for HW3
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290), 1\61870_3.fw(300)

Version 1.5.0.0:

ID: 779420
Support for new gyro sensor
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290), 1\61870_3.fw(300)

Version 1.4.0.0:

ID: 735050
SPI DMA proble fixed (SPI communication can get stuck)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 661970
New firmware
X2X+ problem solved (module failed sometimes at transition from SYNC to GO)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666225
Module documentation revised
Data sheet V 1.06
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(170), 1\61870_2.fw(270)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.5.0.0 * 21.12.2023 5 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.5.0.0:

ID: 779420
Support for new gyro sensor
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290), 1\61870_3.fw(300)

Version 1.4.0.0:

ID: 735050
SPI DMA proble fixed (SPI communication can get stuck)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 661970
New firmware
X2X+ problem solved (module failed sometimes at transition from SYNC to GO)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666225
Module documentation revised
Data sheet V 1.06
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(170), 1\61870_2.fw(270)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.4.0.0 * 02.09.2022 4 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.4.0.0:

ID: 735050
SPI DMA proble fixed (SPI communication can get stuck)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(190), 1\61870_2.fw(290)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 661970
New firmware
X2X+ problem solved (module failed sometimes at transition from SYNC to GO)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666225
Module documentation revised
Data sheet V 1.06
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(170), 1\61870_2.fw(270)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.3.0.0 * 23.07.2021 4 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 661970
New firmware
X2X+ problem solved (module failed sometimes at transition from SYNC to GO)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666225
Module documentation revised
Data sheet V 1.06
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(170), 1\61870_2.fw(270)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.2.0.0 * 09.12.2019 4 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.2.0.0:

ID: 661970
New firmware
X2X+ problem solved (module failed sometimes at transition from SYNC to GO)
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 666225
Module documentation revised
Data sheet V 1.06
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(170), 1\61870_2.fw(270)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.1.0.0 * 25.10.2019 4 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.3.0 * 08.03.2019 4 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.0.3.0:

ID: 634445
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operatingdata were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160),1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.2.0 * 14.06.2018 4 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.0.2.0:

ID: 591335
WIBU Asic Update revised
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No

ID: 596430
Correction register ClrStatistics
Reset-register for humidity, temperature und operating data were not displayed
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.1.0 * 17.04.2018 3 MB EXE AS4_HW_X20CMR111.exe
Popis V4.0 HW Upgrade (X20CMR111)

Revision information X20CMR111

Version 1.0.1.0:

ID: 547035
Support X20CMR111
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61870_1.fw(160), 1\61870_2.fw(260)