DWL@DWL10000816126
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
|---|---|---|---|---|---|---|
| 1.16.0.0 | * | 08.04.2025 | 2 MB | EXE | AS6_HW_X20IF1082-2.exe | |
| Popis |
V6.0 HW Upgrade (X20IF1082-2) Revision information X20IF1082-2 Version 1.16.0.0: ID: RKFY-8616 Support new HW-variant 2 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36365), 1\42915_1.pci(36360), 1\42915_2.pci(36609),1\42915a0.epl(142), 1\42915a1.epl(142), 1\42915a2.epl(143) Version 1.15.0.0: ID: 753135 POWERLINK Manager Type3 und 4 If a CN with the parameter NMTCNSoC2PReq set was operated in a network withPOWERLINK Manager type 3 and 4, this could lead to the error "20803 POWERLINK: A fatal error has occurred" if network disturbances occurred. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36365), 1\42915_1.pci(36360), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.14.0.0: ID: 735705 Update problem If the firmware update of the interface card was interrupted (e.g. by a power failure), it was possible that the interface was no longer booted by Automation Runtime. This problem can only occur with interfaces with revisions ≥ F0 and when the hardware upgrade is changed. To correct this problem, it is necessary to switch to another hardware upgrade. This will force an update or use this current hardware upgrade. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36359), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 705080 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet"and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(36364), 1\42915_1.pci(36357), 1\42915a0.epl(142), 1\42915a1.epl(142) Version 1.11.1.0: ID: 692860 Support HW variant 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 693970 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42915_0.pci(36108), 1\42915_1.pci(36101), 1\42915a0.epl(141), 1\42915a1.epl(141) Version 1.10.0.0: ID: 614145 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644020 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35852), 1\42915a0.epl(140) Version 1.9.0.0: ID: 636510 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed bythe manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(35340), 1\42915a0.epl(138) Version 1.8.0.0: ID: 591100 Documentation updated Version 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 597825 Cannot connect hardware module to PLK2 interface of X20IF1082-2 in Ethernetmode in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 603490 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(34825), 1\42915a0.epl(136) Version 1.7.0.0: ID: 568865 Support HW-Revision DO Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\42915_0.pci(34313), 1\42915a0.epl(134) Version 1.6.0.0: ID: 539750 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(33545), 1\42915a0.epl(131) Version 1.5.0.0: ID: 503425 X20-Compact-S support Channel description changed: No Configuration description changed: No Firmware changed: No ID: 504200 Documentation updated version 1.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.4.0.0: ID: 443850 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32777), 1\42915a0.epl(128) Version 1.3.0.0: ID: 394180 Support of Poll Response Chaining on iCN Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 410330 POWERLINK: Switch to Basic Ethernet of ICN at fail of MN For POWERLNK ICN a switch to basic ethernet mode was build it, so that after a fail of the POWERLINK MN the ICN station could communicate by standard ethernet. In the POWERLINK Standard this state change is not described yet. Now this feature hat to be enabled explicitly therefore the standard behavior of ICN conforms to the POWERLINK specification. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417925 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424025 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424100 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(32521), 1\42915a0.epl(127) Version 1.2.3.0: ID: 358955 POWERLINK MN mode: If "Multiplexing prescale" >= 9, thenthe input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 359175 POWERLINK V2 MN mode: Asynchronousconnection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360195 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values whenCNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360250 POWERLINKV1 MN mode: "Nettime SoC" is not increased. Channel description changed:No Configuration description changed: No Firmware changed: Yes Version 1.2.2.0: ID: 300415 POWERLINK V2 MN mode: It waspossible that an undefined state occurred during booting that caused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 331355 POWERLINKV1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the networkthat also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337465 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting thatcaused the interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(30726), 1\42915a0.epl(120) Version 1.2.1.0: ID: 274800 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 285960 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.2.0.0: ID: 264230 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(29702), 1\42915a0.epl(116) Version 1.1.0.2: ID: 256790 POWERLINK: In controlled nodemode, the I/O mapping was not applied when themanager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256945 POWERLINK: The net time is not always transferred correctly to the application. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265915 POWERLINK V2: If the the Ready-Flag was canceled on the network, the ModuleOK was not cleared. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265870 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(28677), 1\42915a0.epl(112) Version 1.0.2.0: ID: 233570 Correction of interchanged LinkOK data points in AS IO mapping Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 234660 New POWERLINK firmware V106 POWERLINK V2 chainedstations: Reconnecting failed stations improved. LinkOK Datapoint in Operating Mode 'Ethernet' available. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware:1\42915_0.pci(27140), 1\42915a0.epl(106) Version 1.0.1.0: ID:229290 POWERLINK V2 chained stations: When stations that have failed areadded backinto the POWERLINK cycle, active chained stations fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42915_0.pci(26883), 1\42915a0.epl(105) Version 1.0.0.0: ID: 194235 Support of X20IF1082-2 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42915_0.pci(26114), 1\42915a0.epl(102) |
|||||