DWL@DWL10000818687
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
|---|---|---|---|---|---|---|
| 2.17.0.0 | * | 14.05.2025 | 4 MB | EXE | AS6_HW_X67BC81RT.L12.exe | |
| Popis |
V6.0 HW Upgrade (X67BC81RT.L12) Revision information X67BC81RT.L12 Version 2.17.0.0: ID: RKFY-9499 Added capability to disable Fast Link Down detection In the event of interferences on the network cable, the active Fast Link Down Detection very quickly leads to a complete loss of the link and thus to a failure of all subsequent stations. The Fast Link Down Detection can now be deactivated, which means that minor faults on the cable have less impact. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(438), 1\58076_2.fw(438), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.15.0.0: ID: 758820 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(433), 1\58076_2.fw(433), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.14.0.0: ID: 737300 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 737305 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:739445 Module documentation revised Data sheet V2.42 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(432), 1\58076_2.fw(432), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.11.1.0: ID: 697845 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.11.0.0: ID: 602680 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664410 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 664450 DNA: Hub of PLK BC active untilfirst IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665790 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665860 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(430), 1\58076_2.fw(430), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.10.0.0: ID: 634105 Status reply of rtiABRPosrevised The status reply was extended to detect the loss of the reference impulse signal. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 644050 Adaption of internal module communication for large payloads In certain cases, an internal communication problem could occur if large payloads (RES,PAR) weretransmitted. The problem was identified and fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 647965 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(428), 1\58076_2.fw(428), 1\58079_2.fw(440), 1\58079_3.fw(440), 1\58079_4.fw(440) Version 2.9.3.0: ID: 639715 Alignment of AS output according to the FieldBusDesigner Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.9.0.0: ID: 625160 Optimization of hub behavior Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 629035 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629115 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629190 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(427), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.8.0.0: ID: 619225 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 619255 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 621715 Display offurther diagnostic data points in the I / O mapping of the X2X interface fromthe X67 bus controller Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(426), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.6.0.0: ID: 543990 PLK BC not including X2X modules correctlyafter X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 570545 PLK BC not including X2X modules correctly after X2X configuration change Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 590155 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flagsof CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591985 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(425), 1\58079_2.fw(430), 1\58079_3.fw(430), 1\58079_4.fw(430) Version 2.5.6.0: ID: 548865 Module documentation revised Data sheet V1.36 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 551165 Startup time optimizations Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\58076_1.fw(421), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.4.0: ID: 540340 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(419), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.3.0: ID: 523580 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(417), 1\58079_3.fw(410), 1\58079_4.fw(410) Version2.5.2.0: ID: 493915 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(415), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.1.0: ID: 462450 Execution of functionblocks rtiPWM und rtiDiv revised. The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 471680 Harmonization of all reACTION modules Harmonization of hardwarefiles for similar usage and easier maintenance. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 478575 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(410), 1\58079_4.fw(410) Version 2.5.0.1: ID:477320 Extension for AS 4.2.5 Description file adapted for usage inAutomation Studio 4.2.5 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 2.5.0.0: ID: 468160 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468165 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468170 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468565 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(413), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.1.0: ID: 463205 hwx adaption Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.2.0.0: ID: 460130 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.1.0.0: ID: 439125 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439230 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460130 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460250 Error 114834 "Fehler interner SLX-Kommandokanal" beiCPU PowerCycle wenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\58076_1.fw(411), 1\58079_3.fw(310), 1\58079_4.fw(310) Version 1.0.3.0: ID: 432475 hwx-file changes, documentation correction Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.2.0: ID: 395195 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation (English + German) Channel description changed: No Configuration description changed: No Firmware changed: No ID: 424950 Firmware update extended firmware files for hardware variant 4 added Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_3.fw(300), 1\58079_4.fw(300) Version 1.0.1.0: ID: 400650 Status byte added Status reply for power supply added Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.1: ID: 393325 Support X67BC81RT.L12 Support for AutomationStudio incl. documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(300), 1\58079_2.fw(200), 1\58079_3.fw(200) Version 1.0.0.0: ID: 357925 Support X67BC81RT.L12 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58076_1.fw(210), 1\58079_2.fw(105), 1\58079_3.fw(105) |
|||||