General information
| Coding | A |
| Durability |
ROHS 2002/92/EC Can be used in industrial buildings and outdoors |
| Short description | Cable for accelerometer, 15 m |
| Number of pins | 3 |
| Type | Connection cables |
| Cable cross section | |
| AWG | 2x 22 AWG, 1x 24 AWG |
| mm² | 2x 0.34 mm², 1x 0.25 mm² |
Cable construction
| Inner jacket | Halogen-free, shielded |
| Outer jacket | |
| Material | PUR |
| Color | Black gray RAL 7021 |
| Wires | |
| Wire insulation | ≥0.21 mm |
| Wire colors | Brown, blue, black |
| Shield | Braided wire shield made of copper wires, coverage 80% |
| Stranding | 3 wires stranded lengthwise |
Electrical properties
| Conductor resistance | Max. 58 Ω/km (at 20°C) |
| Insulation resistance |
Line: ≥100 GΩ/km (at 20°C) Connector: ≥100 MΩ |
Operating conditions
| Pollution degree per EN 61800-5-1 | 3 |
| Degree of protection per EN 60529 | |
| Cables | IP67 |
| M12 connector | IP67 |
Ambient conditions
| Temperature | |
| Fixed installation | -40 to 80°C |
| Flexible installation | -25 to 80°C |
Mechanical properties
| Dimensions | |
| Length | 15 m |
| Diameter | 4.65 mm ±0.15 mm |
| Bend radius | |
| Fixed installation | 23 mm |
| Flexible installation | 47 mm |
| After installation | 47 mm |
| Can be used in cable drag chains | |
| Drag chain data | |
| Acceleration | 10 m/s² |
| Flex cycles | 10000000 |
| Velocity | 3 m/s |
| Weight | 0.487 kg |
Material number:
0ACC0150.01-1Description:
Cable for accelerometer, length 15 m, 2x 0.34 mm², female M12 connector on the sensor side, can be used in cable drag chains, UL listed
| General | Version (Date) | Download |
|---|---|---|
| Data sheet 0ACCxxx0.01-1 | PDF / 139 KB |