General information
| Input frequency | 100 kHz |
| Power supply | 24 VDC |
| Power consumption | Typ. 6.0 W @ 24 V, the encoder supply (+5 V) draws 500 mA |
| Overvoltage protection | External fuse specified at 10 AT |
| Certifications | |
| UL |
cULus E115267 Industrial control equipment |
Operating conditions
| Mounting orientation | |
| Horizontal | Yes |
| Vertical | Yes |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature | |
| Operation | 0 to 55°C |
| Storage | -20 to 70°C |
| Relative humidity | |
| Operation | 0 to 95%, non-condensing |
Mechanical properties
| Installation | Top-hat rail installation |
| Dimensions | |
| Width | 77 mm |
| Height | 112.5 mm |
| Depth | 58 mm |
Número de material:
0AC401.9Descripción:
The adapter is used as a converter for 5 V encoders. The 5 V differential signals delivered by the encoder are converted to 24 V signals. Absolute and incremental encoders can be used.
| Documentación | Versión (fecha) | Descargar |
|---|---|---|
| Datasheet 0AC401.9 | PDF / 159 KB |