Short description
| Communication module | Controller redundancy link module |
General information
| B&R ID code | 0xC3B4 |
| Status indicators | Module status, bus function |
| Diagnostics | |
| Module status | Yes, using LED status indicator and software |
| Bus function | Yes, using LED status indicator and software |
| Data transfer | Yes, using LED status indicator and software |
| Power consumption | 1.93 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| Certifications | |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267 Industrial control equipment |
| HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV |
Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV |
EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| KC | Yes |
Interfaces
| Fieldbus | Redundancy link |
| Standard (compliance) | IEEE Std 802.3, 2002 edition, clause 38 |
| Variant | 1x duplex LC |
| Transfer rate | 1 Gbit/s |
| Transfer | |
| Physical layer | 1000BASE-SX |
| Wave length | 850 nm |
| Cable fiber type |
Multimode fiber with 62.5/125 µm or 50/125 µm core diameter LC connector on both sides |
| Line length | |
| MMF 50/125 µm | Min.: 2 m, max.: Up to 500 m |
| MMF 62.5/125 µm | Min.: 2 m, max.: Up to 300 m |
Operating conditions
| Mounting orientation | |
| Horizontal | Yes |
| Vertical | Yes |
| Installation elevation above sea level | |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature | |
| Operation | |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section "Derating". |
| Storage | -40 to 85°C |
| Transport | -40 to 85°C |
| Relative humidity | |
| Operation | 5 to 85%, non-condensing |
| Storage | 5 to 85%, non-condensing |
| Transport | 5 to 85%, non-condensing |
Mechanical properties
| Slot | Left IF slot of X20CP368x PLC |
Número de material:
X20IF10X0Descripción:
- Controller-Controller data synchronization module for controller redundancy system
Interface module for redundant operation of controllers.
Información adicional:
Technology information: Redundancia
User's manual: Redundancy for control systems
| Actualizaciones de hardware de Automation Studio | Versión (fecha) | Descargar |
|---|---|---|
| V4.1 HW Upgrade (X20IF10X0) | EXE / 837 KB |
| Documentación | Versión (fecha) | Descargar |
|---|---|---|
| Data sheet X20(c)IF10X0 | PDF / 2 MB | |
| Redundancy for control systems | PDF / 9 MB | |
| X20 Package leaflet ATEX/CSA | PDF / 2 MB | |
| X20 System User´s Manual | PDF / 45 MB |
| E-CAD (plantillas Electro o EPLAN) | Versión (fecha) | Descargar |
|---|---|---|
| X20 EPLAN P8 from V2.4 | EXE / 160 MB |
| M-CAD (plantillas mecánicas) | Versión (fecha) | Descargar |
|---|---|---|
| 3D File DXF/STEP X20IF10X0 | ZIP / 2 MB | |
| 3D File STEP - X20IF10X0 | ZIP / 1 MB |